Related Experiment Video
Updated: Jun 11, 2025

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Dynamic response and vibration suitability analysis of the large-span double-connected structure under coupled wind
Shuwang Yang1, Gang Wang2, Qiang Xu3
1College of Architecture and Engineering, Liaocheng University, Liaocheng, 252000, China.
Abstract:
Modern buildings increasingly utilize lightweight, high-strength materials and feature high-rise, large-span structural designs. These structures often exhibit low natural frequencies and are susceptible to resonance from low-frequency dynamic loads such as wind and pedestrian loads. This paper focuses on a large-span double-connected structure and analyzes its dynamic response under the combined effects of wind and pedestrian loads. First, a finite element model of the structure was created using ANSYS, and model validity verification and modal analysis were performed. Second, a Fourier-based pedestrian model was used to simulate pedestrian loads and generate time-range data. The pulsating wind speed was generated from the Davenport spectrum using the harmonic superposition method. Wind load time-range data were calculated for different heights using Bernoulli's theorem. Finally, the solution yields information about the dynamic response of the structure. The study revealed maximum vertical comfort ratings in the connecting corridor were achieved when crowd density did not exceed 0.3 persons/m2. The connecting corridor's most unfavorable horizontal comfort level was evaluated as a medium, except for the 0-degree wind angle condition. This paper provides experience in studying the dynamic response and vibration suitability assessment of the large-span double-connected structure under wind and pedestrian loads.
Related Concept Videos
Resultant of a General Distributed Loading
Examples such as load distribution due to wind and load distribution on a bridge illustrate how this concept is used to analyze and design safe, reliable structures under variable loading conditions. Most structures, such as residential buildings, bridges, and towers, are...
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Applications of Stress
The...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...