Related Experiment Video
Updated: Aug 4, 2026

Perturbations of Circulating miRNAs in Irritable Bowel Syndrome Detected Using a Multiplexed High-throughput Gene Expression Platform
Published on: November 30, 2016
Minimum information for reporting on the TEER (trans-epithelial/endothelial electrical resistance) assay (MIRTA)
Monita Sharma1, Erin Huber2, Emma Arnesdotter3
1PETA Science Consortium International e.V., 70499, Stuttgart, Germany. monitas@thepsci.eu.
None:
Standard information reporting helps to ensure that assay conditions and data are consistently reported and to facilitate inter-laboratory comparisons. Here, we present recommendations on minimum information for reporting on the TEER (trans-epithelial/endothelial electrical resistance) assay (MIRTA). The TEER assay is extensively used to evaluate the health of an epithelial/endothelial cell culture model and as an indicator of the potential toxicity of a test substance. This publication is the result of an international collaboration─called the RespTox (Respiratory Toxicity) Collaborative─through which twelve laboratories shared their protocols for assessing the barrier function of respiratory epithelial cells using the TEER assay following exposure to substances. The protocols from each laboratory were reviewed to identify general steps for performing the TEER assay, interlaboratory differences between steps, the rationale for differences, whether these differences impact results or cross-laboratory comparisons between TEER measurements. While the MIRTA recommendations are focused on respiratory epithelial cell systems, these recommendations can be adapted for other cell systems that form barriers. The use of these recommendations will support data transparency and reproducibility, reduce challenges in data interpretation, enable cross-laboratory comparisons, help assess study quality, and facilitate the incorporation of the TEER assay into national and international testing guidance.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Total Internal Reflection Fluorescence Microscopy
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...