Related Experiment Video
Updated: Jun 11, 2025

A Standardized Method for Measuring Internal Lung Surface Area via Mouse Pneumonectomy and Prosthesis Implantation
Published on: July 26, 2017
Assessment of hyperinflation: comparison of Global Lung Function Initiative and European Community for Steel and Coal
Sharyn A Roodenburg1,2, Marlies van Dijk1,2, Sonja W S Augustijn1
1Department of Pulmonary Diseases, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands.
Background:
Assessment of static hyperinflation severity is crucial to identify COPD patients eligible for lung volume reduction. The current recommendation of residual volume ≥175% predicted may need to be reconsidered owing to potential differences between the Global Lung Function Initiative (GLI) and the European Community for Steel and Coal (ECSC) reference equations for residual volume and concerns about using percentage of predicted.
Methods:
We compared the residual volume reference values derived from the GLI and ECSC equations using mathematically simulated data and used a receiver operating characteristic curve to establish a new GLI-derived z-score cut-off for residual volume using body plethysmography data from patients with severe COPD.
Results:
The GLI reference equation for residual volume consistently yields a lower predicted residual volume for individuals with an average or below-average height (females ≤163 cm and males ≤177 cm). Our clinical cohort consisted of 1011 patients with COPD (graded using the Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria as 38% GOLD 3 and 59% GOLD 4). In this cohort, a GLI-derived residual volume z-score of ≥2.9 could accurately replace the ECSC-derived 175% predicted cut-off and a z-score of ≥3.5 was established for the 200% predicted cut-off.
Conclusion:
There are substantial differences in predicted residual volume values between the GLI and ECSC equations, with the GLI generally yielding a lower predicted residual volume in the majority of individuals. A GLI-derived residual volume z-score of ≥2.9 could be used to replace the currently used cut-off of ≥175% predicted to identify potential lung volume reduction candidates.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Related Concept Videos
Lung Capacity
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Chronic Obstructive Pulmonary Disease-I: Introduction