Transcatheter Aortic Valve Implantation in Japanese Patients With Large Annulus: The OCEAN-TAVI Registry
Kyohei Onishi1, Kazuki Mizutani1, Kosuke Fujita1
1Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, Osaka, Japan.
Background:
East Asians have smaller aortic valve complexes than individuals from Western countries, and few studies have reported transcatheter aortic valve implantation (TAVI) outcomes in Asian patients with a large annulus.
Objectives:
This study aimed to compare the short- and long-term outcomes of TAVI using balloon-expandable valves (BEVs) and self-expandable valves (SEVs) in Asian patients with a large annulus.
Methods:
The study retrospectively analyzed the data from the OCEAN-TAVI (Optimized Transcatheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry. A large annulus was defined by an annular area ≥500 mm2 and an average diameter ≥25 mm as measured by computed tomography. The primary endpoint was 3-year all-cause mortality. Secondary endpoints were 3-year heart failure rehospitalization (HFR) after TAVI, short-term outcomes of TAVI, and changes in valve function 2 years after TAVI.
Results:
Among 773 patients, 671 underwent BEV TAVI. The SEV TAVI group showed a significantly higher incidence of greater than moderate paravalvular leakage (PVL) (P < 0.001), and an increased pacemaker implantation rate (P = 0.035). The incidence of prosthesis-patient mismatch did not differ between the 2 groups. The Kaplan-Meier curve showed no significant differences in 3-year all-cause mortality and HFR rates (log-rank P = 0.900), and echocardiographic valve function at 2 years post-TAVI did not differ between the 2 groups.
Conclusions:
The lack of differences in postoperative valve performance and long-term prognosis between BEV TAVI and SEV TAVI highlights the importance of selecting valves that can reduce the pacemaker implantation rate and PVL grade in the acute phase in patients with a large annulus. (Optimized Transcatheter Valvular Intervention Transcatheter Aortic Valve Implantation [OCEAN-TAVI]; UMIN000020423).
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Aortic Regurgitation I: Introduction
Coronary Artery Disease V: Surgical Management
Thoracic Aorta
Mitral Valve Prolapse II: Assessment and Management
Aortic Regurgitation IV: Nursing Management
Mitral Regurgitation III: Medical Management