Related Experiment Video
Updated: Jun 11, 2025

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Use of real-time respiratory function monitor improves neonatal face mask ventilation: Cross-over simulation study
Prakash Kannan Loganathan1,2,3, Charlotte Ashton1, Emily Harrold1
1Neonatal Unit, James Cook University Hospital, Middlesbrough, UK.
Background:
Neonatal resuscitation airway training can be difficult as there is no feedback on the face mask technique. "JUNO" is a training respiratory function monitor that provides feedback on mask leak, ventilatory rate, and tidal volume.
Objective:
To evaluate whether the use of the JUNO improves face mask ventilation techniques in manikin models.
Methods:
We conducted an observational cross-over study with our unit staff. Following instructions, each participant performed a single-person technique, followed by a two-person technique with no JUNO feedback. This was repeated with JUNO feedback visible. A similar sequence was performed both in term and preterm manikins, giving a total of 8 sequences. Each participant was instructed to perform 1 min of positive pressure ventilation providing 30 inflations/minute for all of the simulations. Each of the simulation data underwent a data cleaning process.
Results:
Thirty-eight subjects provided a total of 304 sequences of positive pressure ventilation. A total of 13 354 inflations were analyzed. The feedback group had significantly lower rates of inflations with leak >60%, lower rates of excessive tidal volumes, lower mean leak percentage, and a lower mean inspiratory tidal volumes. When analyzed based on the technique (single person and two-person), similar positive results were noted in the "feedback group", across all the strata of staff. All of the staff reported that JUNO improved their ventilation technique and would recommend it for staff training.
Conclusions:
The use of JUNO significantly improved mask ventilation consistently across manikin types, staff roles, and techniques (either single- or two-person).
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...