Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Residuals and Least-Squares Property01:11

Residuals and Least-Squares Property

7.3K
The vertical distance between the actual value of y and the estimated value of y. In other words, it measures the vertical distance between the actual data point and the predicted point on the line
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
7.3K
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

411
This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
411
Computed Tomography01:10

Computed Tomography

4.3K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.3K
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

179
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
179
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

1.2K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
1.2K
Statically Indeterminate Problem Solving01:16

Statically Indeterminate Problem Solving

368
Statically indeterminate problems are those where statics alone can not determine the internal forces or reactions. Consider a structure comprising two cylindrical rods made of steel and brass. These rods are joined at point B and restrained by rigid supports at points A and C. Now, the reactions at points A and C and the deflection at point B are to be determined. This rod structure is classified as statically indeterminate as the structure has more supports than are necessary for maintaining...
368

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Machine Learning-Guided High-Efficiency and Thermally Stable Capacitive Energy Storage in Dielectric Capacitors With a Simple Chemical Composition.

Advanced materials (Deerfield Beach, Fla.)·2026
Same author

Nanomaterial-orchestrated PANoptosis in cancer: Molecular mechanisms, immunological crosstalk, and translational potential.

Journal of controlled release : official journal of the Controlled Release Society·2026
Same author

Bio-Based Hydroxypropyl Methylcellulose Reinforced Water Glass/Silica Sol Hybrid Gel Foam with Synergistic Flame-Retardant and Enhanced Fireproof Performance Under Laboratory Screening Conditions for Forest Fire Barriers.

Materials (Basel, Switzerland)·2026
Same author

A Self-Healing, Transparent, and Hydrophobic Flame-Retardant Coating for Wood Based on Bio-Derived Flame Retardants and Fluorosilane Surface Treatment.

Polymers·2026
Same author

Correction: Chen et al. Chemical Composition of <i>Litsea pungens</i> Essential Oil and Its Potential Antioxidant and Antimicrobial Activities. <i>Molecules</i> 2023, <i>28</i>, 6835.

Molecules (Basel, Switzerland)·2026
Same author

Advanced magnetic resonance neurography for preoperative facial nerve assessment and surgical planning in parotid tumors: a review of current evidence and surgical translation.

Frontiers in oncology·2026
Same journal

LLM-enhanced Neuron Segmentation and Reconstruction in Complex Mouse Brain Images.

IEEE transactions on medical imaging·2026
Same journal

Matrixed-Spectrum Decomposition Accelerated Linear Boltzmann Transport Equation Solver for Fast Scatter Correction in Multi-Spectral CT.

IEEE transactions on medical imaging·2026
Same journal

The Ritz Adjoint Method for MRI Pulse Design.

IEEE transactions on medical imaging·2026
Same journal

Physiology-guided Self-supervised Learning for Simultaneous Dual-Tracer PET Separation.

IEEE transactions on medical imaging·2026
Same journal

Informed-Exploration Reinforcement Learning for Automated Virtual Coronary Intervention Planning.

IEEE transactions on medical imaging·2026
Same journal

4D Reconstruction of Fetal Left Ventricle from Echocardiography via 2.5D Radial Segmentation and Graph-Fourier Reconstruction.

IEEE transactions on medical imaging·2026
See all related articles

Related Experiment Video

Updated: Jun 11, 2025

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

237

Solving Zero-Shot Sparse-View CT Reconstruction With Variational Score Solver.

Linchao He, Wenchao Du, Peixi Liao

    IEEE Transactions on Medical Imaging
    |October 7, 2024
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces the Variational Score Solver (VSS), a novel deep learning method for low-dose computed tomography (CT) reconstruction. VSS achieves high-quality sparse-view CT reconstruction without paired data, outperforming existing unsupervised methods.

    More Related Videos

    Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
    05:05

    Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

    Published on: November 23, 2019

    7.9K
    Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
    14:08

    Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images

    Published on: April 13, 2013

    42.5K

    Related Experiment Videos

    Last Updated: Jun 11, 2025

    Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
    05:32

    Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

    Published on: February 21, 2025

    237
    Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
    05:05

    Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

    Published on: November 23, 2019

    7.9K
    Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
    14:08

    Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images

    Published on: April 13, 2013

    42.5K

    Area of Science:

    • Medical Imaging
    • Artificial Intelligence
    • Radiology

    Background:

    • Computed tomography (CT) is essential for medical diagnosis but involves radiation exposure concerns.
    • Reducing radiation dose in CT compromises image quality and diagnostic accuracy.
    • Existing deep learning methods for CT reconstruction often require paired data, which is difficult to obtain.

    Purpose of the Study:

    • To develop a novel deep learning approach for sparse-view CT reconstruction without paired data.
    • To address the challenge of maintaining image fidelity and diagnostic accuracy while reducing radiation dose in CT scans.

    Main Methods:

    • Introduced the Variational Score Solver (VSS), a method utilizing a latent diffusion model for sparse-view CT reconstruction.
    • Acquired a probability distribution from densely sampled CT reconstructions using a diffusion model.
    • Employed an iterative process integrating the diffusion model as a prior with the data consistency term.
    • Distilled prior knowledge by finding the fixed point of the diffusion model, enabling precise control and a distribution-based approach to reconstruction.

    Main Results:

    • VSS demonstrated superior performance in sparse-view CT reconstruction compared to contemporary unsupervised methods.
    • The method achieved results comparable to advanced supervised methods.
    • Qualitative and quantitative experiments confirmed the effectiveness of VSS in producing high-quality reconstructions.

    Conclusions:

    • VSS offers a novel, unsupervised approach to zero-shot CT reconstruction, overcoming the limitations of supervised learning.
    • The method effectively mitigates radiation concerns by enabling high-quality reconstructions from sparse-view data.
    • VSS represents a significant advancement in low-dose CT imaging and diagnostic accuracy.