Related Experiment Video
Updated: Jun 11, 2025

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Impact of mechanical power on ICU mortality in ventilated critically ill patients: a retrospective study with
Sara Manrique1,2,3, Manuel Ruiz-Botella4, Natalia Murillo5
1Critical Care Department, Hospital Universitario Joan XXIII, Mallafré Guasch 4, 43005, Tarragona, Spain. smanriquemoreno@gmail.com.
Background:
Over the past decade, numerous studies on potential factors contributing to ventilation-induced lung injury have been carried out. Mechanical power has been pointed out as the parameter that encloses all ventilation-induced lung injury-contributing factors. However, studies conducted to date provide data regarding mechanical power during the early hours of mechanical ventilation that may not accurately reflect the impact of power throughout the period of mechanical ventilatory support on intensive care unit mortality.
Methods:
Retrospective observational study conducted at a single center in Spain. Patients admitted to the intensive care unit, > o = 18 years of age, and ventilated for over 24 h were included. We extracted the mechanical power values throughout the entire mechanical ventilation in controlled modes period from the clinical information system every 2 min. First, we calculate the cutoff-point for mechanical power beyond which there was a greater change in the probability of death. After, the sum of time values above the safe cut-off point was calculated to obtain the value in hours. We analyzed if the number of hours the patient was under ventilation with a mechanical power above the safe threshold was associated with intensive care unit mortality, invasive mechanical ventilation days, and intensive care unit length of stay. We repeated the analysis in different subgroups based on the degree of hypoxemia and in patients with SARS CoV-2 pneumonia.
Results:
The cut-off point of mechanical power at with there is a higher increase in intensive care unit mortality was 18 J/min. The greater the number of hours patients were under mechanical power > 18 J/min the higher the intensive care unit mortality in all the study population, in patients with SARS CoV-2 pneumonia and in mild to moderate hypoxemic respiratory failure. The risk of death in the intensive care unit increases 0.1% for each hour with mechanical power exceeding 18 J/min. The number of hours with mechanical power > 18 J/min also affected the days of invasive mechanical ventilation and intensive care unit length of stay.
Conclusions:
The number of hours with mechanical power > 18 J/min is associated with mortality in the intensive care unit in critically ill patients. Continuous monitoring of mechanical power in controlled modes using an automated clinical information system could alert the clinician to this risk.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Cardiopulmonary Resuscitation II: ACLS Airway Management