Clonality Determination by Detecting Unmodified Monoclonal Serum Free Light Chains Using On-Probe Extraction Coupled
Priscilla S W Yeung1,2, Yajing Liu1, Samuel Yang1
1Department of Pathology, Stanford University, Stanford, CA, United States.
Background:
Serum free light chains (FLCs) are an essential clinical biomarker for the diagnosis and monitoring of patients with plasma cell neoplasms. The current widely used immunoassay methods quantify total serum FLCs, which include monoclonal FLCs as well as FLCs in the polyclonal background. Patients with chronic diseases, inflammatory disorders, or renal dysfunction can have elevated total FLCs that lead to ambiguous results. These patients may benefit from a direct measurement of monoclonal FLCs. The purpose of this study was to develop a method that couples on-probe extraction (OPEX) with liquid chromatography-high-resolution mass spectrometry (LC-HR-MS), abbreviated to OPEX-MS, to directly determine the clonality of FLCs.
Methods:
OPEX immunocapture was performed using microprobes loaded with anti-kappa or anti-lambda light chain antibodies. Captured proteins were separated by reversed-phase LC and analyzed by HR-MS.
Results:
Four cohorts of samples from unique patients were tested based on immunoassay FLC results. The LC-HR-MS analysis in the OPEX-MS method provides both a unique retention time along with deconvoluted masses of FLC monomers and dimers for each clone. The study found that 16 out of 49 (33%) kappa FLC elevated samples as well as 83 out of 100 (83%) dual kappa and lambda FLC elevated samples did not have monoclonal FLCs, which is consistent with the knowledge that there is often no clonal population in samples with mildly elevated FLC immunoassay results.
Conclusions:
The OPEX-MS method can serve as a complementary approach to directly determine clonality in patients with difficult-to-interpret FLC immunoassay results.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...