Related Experiment Video
Updated: Jun 11, 2025

Measuring Ascending Aortic Stiffness In Vivo in Mice Using Ultrasound
Published on: December 2, 2014
A noninvasive measurement technique for the initial stiffness of the radial artery
Yixing Zhang1, Xue Feng2, Mingxing Shi3
1AML, Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China; Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing, 100084, China; Institute of Flexible Electronics Technology of THU, Jiaxing, Zhejiang, 314000, China.
Abstract:
Arterial stiffness carries significant implications for cardiovascular disease. Monitoring changes in arterial stiffness is integral to proactive health management, however, current noninvasive methods of quantifying stiffness in vivo rely primarily on linear tangent stiffness, making the measurements vulnerable to the variability of blood pressure and thereby affecting the accuracy in portraying the health status of the arteries. This study proposed a novel methodology for evaluating arterial stiffness that is unaffected by changes in blood pressure. Ultrasound detection techniques are applied to accurately chronicle changes in radial artery diameters across varied blood pressures. Incorporating blood pressure measurements, the initial diameter at cuff blockade, and vessel diameters at systolic and diastolic pressures enables inverse determination of the unstressed initial radial artery stiffness. This method accurately mirrors the results of in vitro experiments employing porcine blood vessels at physiological pressures. The results underscore the technique's ability to quantify arterial mechanical properties precisely. This study offers a groundbreaking strategy for fostering the early detection of atherosclerosis, and aiding artery health regulation.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation