Highly sensitive and selective anodic stripping voltammetric procedure of As(III) determination following double
Iwona Gęca1, Mieczyslaw Korolczuk1
1Department of Analytical Chemistry, Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie Sklodowska University, Maria Curie Sklodowska sq. 3, 20-031, Lublin, Poland.
Abstract:
Double deposition and double stripping steps mode was used for the first time in combination with a flow system for anodic stripping voltammetric determination of As(III) ions. The proposed way of the voltammetric measurements leads to a decrease of the detection limit as compared to the values obtained using a traditional three-electrode system thanks to an initial preconcentration of the analyte on the first working electrode as well as the significant increase of the selectivity of As(III) determination thanks to the application of a flow system. Optimization of the analytical procedure was performed. The calibration curve of As(III) determination was a straight line in the range from 1 × 10-9 to 5 × 10-8 mol L-1. The estimated detection limit was 4.8 × 10-10 mol L-1 (deposition time of 120 s at both working electrodes). The repeatability of the proposed procedure calculated as RSD% for As(III) at a concentration of 1 × 10-8 mol L-1 was 3.8 % (n = 7). The tolerable limit of Cu(II) excess was significantly increased thanks to the solution exchange after the first deposition step. The correctness of the proposed procedure was confirmed by analysis of a real water sample and lake water certified reference material by obtaining satisfactory recovery values.
More Related Videos
08:34A Dual-Functional Electroactive Filter Towards Simultaneously SbIII Oxidation and Sequestration
Published on: December 5, 2019
10:27Simultaneous Multi-surface Anodizations and Stair-like Reverse Biases Detachment of Anodic Aluminum Oxides in Sulfuric and Oxalic Acid Electrolyte
Published on: October 5, 2017
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...