Hybrid modality dual-energy imaging aggregating complementary advantages of kV-CT and MV-CBCT: concept proposal and
Junfeng Qi1, Shutong Yu2, Zhengkun Dong3
1Department of Engineering Physics, Tsinghua University, Haidian District, Beijing, P. R. China, Beijing, Beijing, 100084, CHINA.
Objective:
Megavoltage cone-beam CT (MV-CBCT) is advantageous in metal artifact reduction during Image-Guided Radiotherapy (IGRT), although it is limited by poor soft tissue contrast. This study proposed and evaluated a novel hybrid modality dual-energy (DE) imaging method combining the complementary advantages of kV-CT and MV-CBCT. Approach: The kV-CT and MV-CBCT images were acquired on a planning CT scanner and a Halcyon linear accelerator respectively. After rigid registration, images of basis materials were generated using the iterative decomposition method in the volumetric images. The decomposition accuracy was quantitatively evaluated on a Gammex 1472 phantom. The performance of contrast enhancement and metal artifact reduction in virtual monochromatic images were evaluated on both phantom and patient studies. Main results: Using the proposed method, the mean percentage errors for RED and SPR were 0.90% and 0.81%, outperforming the clinical single-energy mapping method with mean errors of 1.28% and 1.07%, respectively. The contrasts of soft-tissue insets were enhanced by a factor of 2~3 at 40 keV compared to kV-CT. The standard deviation in the metal artifact area was reduced by ~67%, from 42 HU (kV-CT) to 14 HU (150 keV monochromatic). The head and neck patient test showed that the percent error of soft-tissue RED in the metal artifact area was reduced from 18.1% (HU-RED conversion) to less than 1.0% (the proposed method), which was equivalent to the maximum dosimetric difference of 28.7% based on the patient-specific plan. Significance: Without hardware modification or extra imaging dose, the proposed hybrid modality method enabled kV-MV DE imaging, providing improved accuracy of quantitative analysis, soft-tissue contrast and metal artifact suppression for more accurate IGRT. .
More Related Videos
07:13Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
Published on: October 27, 2023
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
X-ray Imaging