Related Experiment Video
Updated: Jun 11, 2025

High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
Published on: April 16, 2017
Supernormal Temperature Sensing Performance Realized through the Blue Emitting Level of Er3+ along with Detection
Guotao Xiang1, Ming Xiong1, Zhiyu Yang1
1Department of Mathematics and Physics, Chongqing University of Posts and Telecommunications, Chongwen Road, Chongqing 400065, China.
Abstract:
Fluorescence intensity ratio (FIR)-type optical thermometers based on thermally coupled energy levels (TCLs) of rare earth ions are suitable candidates for noncontact temperature detection in living organisms, microelectronics apparatus, and so forth. Therefore, the improvement of the thermometric sensitivity of TCL-based thermometers has become a research hotspot in recent years. Herein, ultrahigh sensitivity and outstanding resolution for temperature sensing have been realized in YNbO4: Yb3+/Er3+. Unusually, the thermally coupled three-level system of Er3+: 4F7/2/2H11/2/4S3/2 is first employed for optical thermometry based on FIR technology. A supernormal thermometric sensitivity of 2.67% K-1 is obtained from the thermally coupled 4F7/2 and 4S3/2 states due to the large energy gap between them, significantly surpassing that of most temperature sensors in the same category. Furthermore, the existence of the intermediate level 2H11/2 can effectively prevent the decoupling effect between 4F7/2 and 4S3/2. Additionally, the temperature sensing behavior realized by the Stark sublevels of the Er3+: 4I13/2 → 4I15/2 transition, with a penetration depth of 8 mm, shows the potential of temperature measurement in deep biological tissues, benefiting from its excitation and emission wavelengths located in the biological window. All of the data reveal that YNbO4: Yb3+/Er3+ is an ultrasensitive optical thermometer and exhibits the capacity of temperature detection in deep tissues.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

