Fire performance of CFRP-strengthened piloti-type columns with fire-resistant materials during standard fire exposure
Jinwon Shin1, Hansol Lee1, In-Rak Choi2
1Department of Architectural Engineering, Catholic Kwandong University, Gangneung, Korea.
Abstract:
This paper presents a numerical investigation into the fire endurance of carbon fiber reinforced polymer (CFRP)-strengthened columns, shielded with fire-resistant materials, in piloti-type reinforced concrete buildings. The strengthened column, equipped with a fire protection system, underwent exposure to the ASTM E119 standard time-temperature curve for a duration of 4 h. To comprehensively evaluate the thermal and structural performance of the strengthened column at elevated temperatures and substantiate the effectiveness of the fire protection system, a fully coupled thermal-stress analysis was conducted. The numerical modeling approach employed in this study was rigorously validated through previous experimental studies in conjunction with adherence to the ACI design guideline, specifically ACI 440.2R-17. Using the validated structural fire model, the thermal and structural behaviors of the RC column with an insulated CFRP strengthening system were investigated based on four key performance criteria: glass transition temperature, ignition temperature of polymer matrix, critical temperature of reinforcing bars, and the design axial load capacity at elevated temperatures. Furthermore, a comparative assessment of fire endurance was performed using diverse fire-resistant materials, including Sprayed Fire-Resistive Material (SFRM) and Sikacrete®-213 F, with insulation thicknesses ranging from 10 to 30 mm, during the 4-hour fire exposure period.
More Related Videos
10:29Experimental Methodology for Estimation of Local Heat Fluxes and Burning Rates in Steady Laminar Boundary Layer Diffusion Flames
Published on: June 1, 2016
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Fiber Reinforced Concrete
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Design of Prismatic Beams for Bending
Design of Columns under an Eccentric Load
Design Consideration
The factor of safety is another key...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...