Related Experiment Video
Updated: Jun 11, 2025

Quantitative Autonomic Testing
Published on: July 19, 2011
Comparison of two techniques of administering the Valsalva manoeuvre in patients under general anaesthesia: A
Shagun B Shah1, Vineet Chaudhary2, Rajiv Chawla1
1Department of Anaesthesia and Critical Care, Rajiv Gandhi Cancer Institute and Research Centre, Rohini, Delhi, India.
Background And Aims:
Surgeons often request a Valsalva manoeuvre (VM) at the end of surgery (head-neck surgery, craniotomy) to check haemostasis and to unmask covert venous bleeders. We aimed to compare an anaesthesia machine-generated objective technique for delivering VM under pressure-control (PC) mode with the traditional subjective technique of delivering VM in manual mode.
Methods:
This randomised controlled study included 60 adult patients randomised to manual (Group M) and controlled ventilation (Group C) groups. Our primary outcome measure was internal jugular vein (IJV) diameter at pre-determined time points (T0 = baseline, T1 = VM initiation, T2 = 20 s after VM initiation, T3 = immediately after VM release, and T4 = 1 min, T5 = 2 min and T6 = 5 min post-VM release). Secondary outcome measures included mean arterial pressure (MAP), heart rate, time to desired plateau airway pressure, number of patients with bleeders unmasked and surgeon satisfaction. Independent/paired sample t-tests were applied. Results are expressed as mean (standard deviation), mean difference (95% confidence interval), dotted box-whisker plots and trendlines. P <0.05 is considered statistically significant.
Results:
Mean differences in diameter changes in IJV (in centimetres) in the mediolateral and anteroposterior directions between Group C and Group M were -0.136 (-0.227, -0.044) and -0.073 (-0.143, -0.002), respectively. VM in the PC mode produced more significant IJV dilatation (P = 0.004, P = 0.044). MAP at T0 and T1 was comparable. At T2 and T3, there was a more significant fall in MAP in Group C versus Group M (P = 0.018 and P = 0.021, respectively). At T4, T5 and T6, MAP was comparable.
Conclusion:
Performing VM in PC mode is a better technique based on IJV diameter, haemodynamics, bleeder unmasking and surgeon satisfaction.
More Related Videos
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
Skeletal Muscle Relaxants: Therapeutic Uses
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...