Coordination of protection and operation in micro-grids with inverter based distributed generation using SAOA
Mohammad Hassan Tanha1, Majid Gandomkar1, Javad Nikoukar1
1Department of Electrical Engineering, College of Engineering Technology, Saveh Branch, Islamic Azad University, Saveh, Iran.
Abstract:
In the proposed protection coordination scheme, the depreciation of the operation time of the entire relay in the primary and backup protection modes for all possible fault locations is considered as the objective function. The limitations of this problem include the equations for calculating the operation time of the relays in both forward and reverse directions, the limitation of the coordination time interval, the limitation of the setting parameters of the proposed relays, the restriction of the size of the reactance that limits the fault current, and the limitation of the standing time of distributed generation per small signal fault. The operation time of the relays depends on the short circuit current passing through them, so it is necessary to calculate the network variables before the fault occurs. For this purpose, optimal daily power distribution should be used in the micro-grid, because micro-grids consist of storage and renewable resources. The proposed plan includes the uncertainties of consumption and generation capacity of renewable resources. Then, to achieve a reliable answer with a low standard deviation, the refrigeration optimization algorithm is used to solve the proposed problem. Finally, the proposed design is implemented on the standard test system in the MATLAB software, and then the capabilities of the proposed design are examined.
Related Concept Videos
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Power System Distribution
The transmission system is designed...
Conservation of AC Power
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Generator Voltage Control
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...