Related Experiment Video
Updated: Jul 27, 2026

Attaching Biological Probes to Silica Optical Biosensors Using Silane Coupling Agents
Published on: May 1, 2012
Highly sensitive colorimetric detection of Cd(ii) based on silica sol modified with dithizone and cationic surfactant
Arpaporn Litluechai1, Arreerat Prompa1, Pikaned Uppachai2
1Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University Khon Kaen 40002 Thailand.
Abstract:
The cadmium ion (Cd2+) is highly poisonous and nondegradable and easily bioaccumulates through the food chain. Therefore, it is crucial to develop cost-effective chemical sensors for Cd2+ with fast response time, high selectivity, and very low detection limits. In this study, a colorimetric sensor for the determination of Cd2+ was fabricated by modifying silica sol with dodecyltrimethylammonium bromide (DTAB) and dithizone (DZ). Cd2+ formed a complex with DZ, changing the solution color immediately from purple to orange prior to detection using ultraviolet-visible spectrophotometry and a customized Cd analyzer for the precipitate. Under the optimum conditions, the developed Cd2+ sensor had a linear range of 0.01-0.25 mg L-1, a low limit of detection of 5.0 μg L-1, and outstanding repeatability. This sensor also showed good precision, with the relative standard deviations of less than 2.59% and 3.24% for the intra- and inter-day data, respectively. The proposed colorimetric method was successfully applied to determine Cd2+ in environmental water samples, and the results were comparable to those obtained using standard atomic absorption spectrometry. Moreover, quantitative analysis was conducted using the customized Cd analyzer to estimate the color intensity change, without requiring sophisticated scientific instruments. This colorimetric sensor can be used for the portable, cost-effective, and rapid on-site detection of Cd2+ in environmental water samples.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
05:30Author Spotlight: Streamlining PCR Methods for Enhanced Accessibility and Efficiency
Published on: March 1, 2024
Related Concept Videos
UV–Vis Spectrometers
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Determination of Crystal Structures