Comparison of ocular biometric measurements and intraocular lens power calculation using different methods in eyes
Ramin Salouti1,2, Mostafa Nazarpour-Servak3,4, Kia Salouti5
1Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
Abstract:
This prospective cohort study included 80 healthy candidates for Implantable Collamer Lens (ICL) implantation who underwent biometric assessments with Scheimpflug imaging (the Pentacam-AXL) and swept-source optical coherence tomography (SS-OCT; the IOLMaster-700), both before and 3 months after surgery. The main outcome measures were mean keratometry, anterior chamber depth, axial length, and various intraocular lens (IOL) calculation formulas (Haigis, SRK/T, Hoffer Q, Holladay 1, Barrett Universal 2, and Olsen). The interchangeability of the devices was assessed by generating 95% limits of agreement (95% LoA) and associated Bland-Altman plots. The average age of the participants was 31.5 ± 5.4 years (22-43), with 58 (72.5%) being female. Among the cases analyzed, 11 (13.4%) had incorrect anterior lens surface segmentation using the IOLMaster-700, and 1 case (1.2%) had inappropriate segmentation using the Pentacam-AXL. Postoperative IOL power calculation resulted in readings that were, on average, 0.15 to 0.30 D higher compared to preoperative measurements. The 95% LoAs could differ by up to 0.85 D higher after surgery, indicating weak agreement between pre- and postoperative measurements. There was poor agreement between the IOLMaster-700 and Pentacam-AXL in IOL power calculation for eyes with post-ICL implantation, with a difference of more than 1 D in the 95% LoAs. In conclusion, Scheimpflug imaging was found to be less susceptible than the SS-OCT technique to segmentation errors of the anterior lens surface after ICL implantation. Neither device showed interchangeable results for pre- versus postoperative IOL power calculation. The determination of IOL power by the IOLMaster-700 versus Pentacam-AXL was not interchangeable in eyes with ICL implantation.
More Related Videos
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017