A novel artificial neural network based selection harmonic reduction technique for single source fed high gain

Anand Kumar Thangapandi1, Amit Kumar2, Durgalakshmi Karthigeyan1

  • 1Department of Electrical and Electronics Engineering, Dr. Mahalingam College of Engineering and Technology (Autonomous), India.

Heliyon
|October 15, 2024
PubMed

Related Concept Videos

Half wave rectifier01:20

Half wave rectifier

A half-wave rectifier is a fundamental circuit in electronics, designed to convert alternating current (AC) voltage into a unidirectional voltage. It utilizes the simplest form of diode rectification, where the circuit comprises a single diode in series with a load resistor and an AC power source.
929
Full wave rectifier01:22

Full wave rectifier

A full-wave rectifier is a device that converts alternating current (AC) to direct current (DC) and is more efficient than its half-wave counterpart. It typically includes a center-tapped transformer, two diodes, and a load resistor. The secondary winding of the transformer is divided to provide two equal voltages of opposite polarities, which is the pivotal element of full-wave rectification.
876
Voltage Doubler Circuit01:23

Voltage Doubler Circuit

A voltage doubler circuit integrates two main components: a clamping section and a rectifier section. The clamping section consists of a capacitor (C1) and a diode (D1), whereas the rectifier section is equipped with another diode (D2) and capacitor (C2). This circuit produces an output voltage with twice the amplitude of the sinusoidal input voltage.
487
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
839
Generator Voltage Control01:21

Generator Voltage Control

Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
128
Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
398