Related Experiment Video
Updated: Jun 10, 2025

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Seismic response comparison of various geogrid reinforced earth-retaining walls: based on shaking table and 3D FE
Muhammad Akbar1,2, Pan Huali3, Jiangcheng Huang4
1Institute of Mountain Hazards and Environment, Chinese Academy of Sciences, Chengdu, 610299, China.
Abstract:
The performance of various geogrid earth-retaining walls integrated with a non-cohesion granular backfill for reducing earth pressure has been investigated through small-scale shaking table tests and full-scale 3D finite element analysis. This purpose involved a series of physical modeling tests involving different earth-retaining walls (0.83 cm, height 7.5 cm, thickness, and length 1 m) and arrangements of full-scale 3D finite element analysis (5 m, height, 0.3 m, thickness, and length 6 m). This research investigates and designs hollow prefabricated concrete panels, gravity-type stone masonry, and reinforcement concrete (GRE) walls. It also displays comparative studies such as the top displacement of the wall, deflection of the wall, lateral pressure of the wall, settlement of the backfill, and vertical settlement of the foundation across the height of the (GRE) walls. The understanding and findings based on shaking table experiments and FE simulations have been used to develop a critical model for estimating earthquake-induced displacement (GRE) walls. The validity of the proposed FE simulation model has also been examined in the shaking table experiment and the FE simulation results. Based on the findings, the hollow prefabricated concrete panels were the most practical alternative due to their lower deflection and displacement. The observation also found that the hollow prefabricated (GER) wall is the most viable option, as the backfill surface settlement and lateral pressure decreased with the inclusion of geogrid reinforcement.
More Related Videos
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
Related Concept Videos
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Method of Sections: Problem Solving II
Non-destructive Tests for Concrete Strength
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...