Objective:
To determine if a novel CPAP system is associated with physiologic improvement in premature infants in a low resource setting and if the introduction of blended oxygen would reduce FiO2.
Study Design:
Feasibility study of infants ≤2000 g or ≤32 weeks gestational age with early respiratory distress who were placed on Vayu CPAP with continuous pulse oximetry. Physiologic parameters were recorded prior to initiation and through the first 24 h.
Results:
Seventy-six infants of birthweight 1360 ± 324 g and gestational age 31.2 ± 2.5 weeks were included. Compared to baseline, heart rate, respiratory rate, FiO2, and Silverman Anderson score significantly decreased while oxygen saturations significantly increased at one hour with persistence through 24 h.
Conclusion:
Utilization of Vayu CPAP in premature infants with respiratory distress was associated with immediate improvement in physiologic parameters. Use of blended oxygen coupled with pulse oximetry facilitates reduction in delivered oxygen.
More Related Videos
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...