Related Experiment Video
Updated: Jun 10, 2025

An “All-laser” Endothelial Transplant
Published on: July 6, 2015
Crosslinked All-Femtosecond Laser-Cut Corneal Allogenic Intracorneal Ring Segments (AFXL CAIRSs): Pilot Ex Vivo Study
Cosimo Mazzotta1,2,3, Marco Zagari4, Giulia Bona4
1Department of Medicine, Surgery and Neurosciences, Postgraduate Ophthalmology School, Siena University, 53035 Siena, Italy.
Abstract:
Objectives: This pilot ex vivo study and first clinical experience in Italy evaluate the impact of using pre-implantation crosslinking on all-femtosecond laser-cut corneal allogenic intracorneal ring segments (AFXL CAIRSs). Methods: Six human donor eye-bank corneas were used for this preclinical ex vivo human study. Three donor (D) corneas were used for AFXL CAIRSs. First, they were prepared with an IntraLase™ femtosecond laser (Johnson & Johnson, New Brunswick, NJ, USA). The allogenic tissue rings were crosslinked before implantation with Riboflavin-UV-A accelerated crosslinking protocol (ACXL) with a 0.1% HPMC Riboflavin isotonic solution (Vibex Rapid, Glaukos-Avedro, Burlington, MA, USA) and a new KXL UV-A emitter (Glaukos-Avedro, USA). Three corneas were used as recipients (Rs) of the AFXL CAIRSs. After completing the ex vivo phase, IRB approval and signing a specific informed consent, the first two Italian patients were treated. A single ACXL CAIRS was implanted in a 51-year-old male with 53.53 D K steep, 363 μm minimum corneal thickness (MCT) and a double ACXL CAIRS was implanted in a 46-year-old male patient with 58.30 D K steep, 443 μm MCT. The longest follow-up was at three months. Results: Crosslinking of the segments enhanced tissue stiffness and grip, facilitating manipulation and CAIRS insertion into the recipient tunnels, and the yellowish color of the crosslinked segments improved visibility. The segment's thickness and volume remained unaltered during the follow-up. Both patients improved UDVA and BSCVA. K steep and High-Order Aberrations (HOAs) were reduced and MCT increased. Conclusions: Pre-implantation ACXL facilitated CAIRS insertion preserving dimensions and volume during the follow-up, rendering this important step a promising candidate in method standardization. Functional data and MCT improved significantly without adverse events.
More Related Videos
11:42Combination of Microstereolithography and Electrospinning to Produce Membranes Equipped with Niches for Corneal Regeneration
Published on: September 12, 2014
12:36A Human Corneal Organ Culture Model of Descemet's Stripping Only with Accelerated Healing Stimulated by Engineered Fibroblast Growth Factor 1
Published on: July 22, 2022