Related Experiment Video
Updated: Jun 10, 2025

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Capillary Refill Time as a Part of Routine Physical Examination in Critically Ill Patients Undergoing Vasoactive
Fabian Wesołek1, Zbigniew Putowski2, Wiktoria Staniszewska1
1Students' Scientific Society, Department of Acute Medicine, School of Medicine in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland.
Abstract:
Background/Objectives: In critically ill patients, achieving a mean arterial pressure (MAP) of 65 mmHg is a recommended resuscitation goal to ensure proper tissue oxygenation. Unfortunately, some patients do not benefit from providing such a value, suggesting that other indices are needed for better hemodynamic assessment. Capillary refill time (CRT) has emerged as an established marker for peripheral perfusion and a therapeutic target in critical illness, but its relationship with other exponents of hypoperfusion during vasopressor support after resuscitation period still warrants further research. This study aimed to investigate whether in critically ill patients after initial resuscitation, CRT would provide information independent of other, readily accessible hemodynamic variables. Methods: Critically ill patients who were mechanically ventilated after the resuscitation period and receiving vasopressors were prospectively studied between December 2022 and June 2023. Vasopressor support was measured using norepinephrine equivalent doses (NEDs). CRT, MAP and NED were assessed simultaneously and analyzed using Spearman's rank correlation. Results: A total of 92 patients were included and 210 combined MAP-CRT-NED-Lactate records were obtained. There was no correlation between CRT and MAP (R = -0.1, p = 0.14) or lactate (R = 0.11, p = 0.13), but there was a positive weak correlation between CRT and NED (R = 0.25, p = 0.0005). In patients with hypotension, in 83% of cases (15/18), CRT was within normal range, despite different doses of catecholamines. When assessing patients with high catecholamine doses, in 58% cases (11/19), CRT was normal and MAP was usually above 65 mmHg. Conclusions: Capillary refill time provides additional hemodynamic information that is not highly related with the values of mean arterial pressure, lactate level and vasopressor doses. It could be incorporated into routine physical examination in critically ill patients who are beyond initial resuscitation.
More Related Videos
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pre-Procedural Guidelines for Assessing Blood Pressure
Pulse
The pulse serves as a clinical...

