Related Experiment Video
Updated: Jun 10, 2025

A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response
Published on: January 7, 2019
A Study on Sensitivity Improvement of the Fiber Optic Acoustic Sensing System Based on Sagnac Interference
Ruixi Tang1, Hongcheng Zhao1, Juqin Feng1
1The Key Laboratory of Electromagnetic Technology and Engineering, Nanchong of Sichuan, China West Normal University, Nanchong 637000, China.
Abstract:
A new pickup structure was introduced and modified to improve the resolution of the linear Sagnac optical fiber acoustic sensing system. The maximum strains corresponding to the material, diameter, wall thickness, and height of the pickups were analyzed by simulation. An aluminum cylinder with a diameter of 110 mm, a wall thickness of 3 mm, and a height of 120 mm was chosen as the basic pickup. A four-groove pickup with a vertical width of 80 mm and a horizontal width of 20 mm was introduced to improve the sensitivity of the system. The experiments showed that the average peak-to-peak sensitivity of the four-groove pickup increased by 215.54% to 106.806 mV/Pa. The improved pickup can be applied in areas to monitor the situation of invasion of the Sagnac optical fiber acoustic sensing system.