Joint Power Allocation and Hybrid Beamforming for Cell-Free mmWave Multiple-Input Multiple-Output with Statistical

Jiawei Bai1, Guangying Wang2, Ming Wang3

  • 1College of Electronic and Information Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China.

PubMed

Related Concept Videos

Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
237
The Maximum Power Transfer Theorem01:20

The Maximum Power Transfer Theorem

Consider a linear AC Thevenin equivalent circuit connected to a load impedance.
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
563
Shearing Stresses in a Beam: Problem Solving01:14

Shearing Stresses in a Beam: Problem Solving

A cantilever beam with a rectangular cross-section under distributed and point loads experiences shearing stresses. The analysis begins by identifying the loads acting on the beam. Then, the reactions at the beam's fixed end are calculated using equilibrium equations. The vertical reaction is a combination of the distributed and point loads, while the moment reaction is the sum of their moments. The shear force distribution along the beam, resulting from these loads, is established by...
168
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
96
The Power Superposition Principle01:19

The Power Superposition Principle

Consider a circuit with two sinusoidal voltage sources. Each one influences the circuit independently, and the superposition principle helps us understand the combined effect by adding up the responses from each source.
146
Shear on the Horizontal Face of a Beam Element01:16

Shear on the Horizontal Face of a Beam Element

To understand shear on the flat side of a prismatic beam element, consider the vertical and horizontal shearing forces, and the normal forces, acting on the element. The element's upper (U) and lower (L) sections, which are divided by the beam's neutral axis, are examined. The equilibrium of these forces is determined by applying the equilibrium equation, which helps identify the horizontal shearing force. This force is directly related to the bending moments and the cross-section's...
159