Experimental Research on Dynamic Mechanical Properties of High-Density Foamed Concrete
Menghui Guo1,2,3, Yongsheng He3, Xudong Zhi1,2
1Key Lab of Structures Dynamic Behaviour and Control of the Ministry of Education, Harbin Institute of Technology, Harbin 150090, China.
Abstract:
Foamed concrete is increasingly utilized in protection engineering because it offers a high energy absorption ratio and a relatively low construction cost. To investigate the dynamic properties of foamed concrete, a series of dynamic compression tests are carried out on high-density foamed concrete with densities of 800 kg/m3, 1000 kg/m3, and 1100 kg/m3 under a strain rate range of 59.05 s-1~302.17 s-1 by using a Φ-100 mm split Hopkinson pressure bar (SHPB) device. The effects of strain rate on the stress-strain relationship, dynamic compressive strength, and dynamic increase factor of foamed concrete are discussed in detail. The results show that the dynamic mechanical characteristics of foamed concrete with different densities exhibit a significant strain rate enhancement effect. Additionally, the energy absorption characteristics of foamed concrete are investigated, demonstrating that it can effectively prevent the transmission of incident energy and that its energy absorption efficiency declines as the strain rate increases. A high-speed camera was also employed to capture the failure process of foamed concrete. The results exhibit that fracture production and development induce the failure of foamed concrete, the failure process of foamed concrete advances as the strain rate increases, and the failure mode becomes increasingly severe.
More Related Videos
09:22Casting Protocols for the Production of Open Cell Aluminum Foams by the Replication Technique and the Effect on Porosity
Published on: December 11, 2014
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Effects of Air-entrainment in Concrete
Fiber Reinforced Concrete
Fatigue Strength of Concrete
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
