Related Experiment Video
Updated: Jun 10, 2025

The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
Combined Active and Passive Isothermic Heating Leads to Similar Core Temperature Compared With Exercise Alone
Floris C Wardenaar1, Sonia Navarro1, Rachel Caballero1
1College of Health Solutions, Arizona State University, Phoenix.
Context:
The training stress of heat acclimatization optimizing exercise performance in a hot environment can be demanding.
Objective:
This study evaluated the efficiency of different single heating protocols to elevate core temperature.
Design:
Nonrandomized controlled trial.
Setting:
Laboratory.
Patients Or Other Participants:
Ten male participants (age = 25 ± 3 years) performed 4 different 60-minute heating strategies at least 1 week apart.
Interventions:
Sixty minutes passive heating (PAS), 30 minutes active heating using a high-intensity bike protocol (HIBP) in a hot environment with 30 minutes passive heating (EH-PAS), 60 minutes HIBP in a hot environment (EH), or 60 minutes HIBP at room temperature (EM).
Main Outcome Measure(S):
Body core temperature and heart rate.
Results:
The highest peak gastrointestinal temperature occurred in EH-PAS (39.1 ± 0.4°C), followed by EH (38.9 ± 0.3°C), EM (38.4 ± 0.3°C), and PAS (38.1 ± 0.5°C). The average heart rate, measured as a control for intensity, was not different between exercise strategies (EH-PAS = 142 ± 12.3 beats per minute [bpm], EH = 146 ± 9.7 bpm, and EM = 142 ± 13.3 bpm; P > .05), but was different for PAS (98 ± 15.2 bpm; P < .05).
Conclusions:
Adding passive heating to a shorter exercise protocol can be just as effective in keeping core temperature elevated as exercise in the heat alone during a 60-minute session. Therefore, a single-bout combination of exercise and passive heating may result in a similar body temperature induction compared with exercise heat stress alone.
More Related Videos
08:22Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...