CATransformer: A Cycle-Aware Transformer for High-Fidelity ECG Generation From PPG
None:
Electrocardiography (ECG) is the gold standard for monitoring heart function and is crucial for preventing the worsening of cardiovascular diseases (CVDs). However, the inconvenience of ECG acquisition poses challenges for long-term continuous monitoring. Consequently, researchers have explored non-invasive and easily accessible photoplethysmography (PPG) as an alternative, converting it into ECG. Previous studies have focused on peaks or simple mapping to generate ECG, ignoring the inherent periodicity of cardiovascular signals. This results in an inability to accurately extract physiological information during the cycle, thus compromising the generated ECG signals' clinical utility. To this end, we introduce a novel PPG-to-ECG translation model called CATransformer, capable of adaptive modeling based on the cardiac cycle. Specifically, CATransformer automatically extracts the cycle using a cycle-aware module and creates multiple semantic views of the cardiac cycle. It leverages a transformer to capture detailed features within each cycle and the dynamics across cycles. Our method outperforms existing approaches, exhibiting the lowest RMSE across five paired PPG-ECG databases. Additionally, extensive experiments are conducted on four cardiovascular-related tasks to assess the clinical utility of the generated ECG, achieving consistent state-of-the-art performance. Experimental results confirm that CATransformer generates highly faithful ECG signals while preserving their physiological characteristics.
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Transformers with Off-Nominal Turns Ratios
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Instrument Transformers