Related Experiment Video
Updated: Jun 26, 2026

MR Molecular Imaging of Prostate Cancer with a Small Molecular CLT1 Peptide Targeted Contrast Agent
Published on: September 3, 2013
Achieving accurate prostate auto-segmentation on CT in the absence of MR imaging
Jingwei Duan1, Riley C Tegtmeier2, Carlos E Vargas3
1Mayo Clinic Arizona, Phoenix, AZ, United States; The University of Alabama at Birmingham, Birmingham, AL, United States.
Background:
Magnetic resonance imaging (MRI) is considered the gold standard for prostate segmentation. Computed tomography (CT)-based segmentation is prone to observer bias, potentially overestimating the prostate volume by ∼ 30 % compared to MRI. However, MRI accessibility is challenging for patients with contraindications or in rural areas globally with limited clinical resources.
Purpose:
This study investigates the possibility of achieving MRI-level prostate auto-segmentation accuracy using CT-only input via a deep learning (DL) model trained with CT-MRI registered segmentation.
Methods And Materials:
A cohort of 111 definitive prostate radiotherapy patients with both CT and MRI images was retrospectively grouped into training (n = 37) and validation (n = 20) (where reference contours were derived from CT-MRI registration), and testing (n = 54) sets. Two commercial DL models were benchmarked against the reference contours in the training and validation sets. A custom DL model was incrementally retrained using the training dataset, quantitatively evaluated on the validation dataset, and qualitatively assessed by two different physician groups on the validation and testing datasets. A contour quality assurance (QA) model, established from the proposed model on the validation dataset, was applied to the test group to identify potential errors, confirmed by human visual inspection.
Results:
Two commercial models exhibited large deviations in the prostate apex with CT-only input (median: 0.77/0.78 for Dice similarity coefficient (DSC), and 0.80 cm/0.83 cm for 95 % directed Hausdorff Distance (HD95), respectively). The proposed model demonstrated superior geometric similarity compared to commercial models, particularly in the apex region, with improvements of 0.05/0.17 cm and 0.06/0.25 cm in median DSC/HD95, respectively. Physician evaluation on MRI-CT registration data rated 69 %-78 % of the proposed model's contours as clinically acceptable without modifications. Additionally, 73 % of cases flagged by the contour quality assurance (QA) model were confirmed via visual inspection.
Conclusions:
The proposed incremental learning strategy based on CT-MRI registration information enhances prostate segmentation accuracy when MRI availability is limited clinically.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging