Revolution or risk?-Assessing the potential and challenges of GPT-4V in radiologic image interpretation
Marc Sebastian Huppertz1, Robert Siepmann2, David Topp2
1Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany. mhuppertz@ukaachen.de.
Objectives:
ChatGPT-4 Vision (GPT-4V) is a state-of-the-art multimodal large language model (LLM) that may be queried using images. We aimed to evaluate the tool's diagnostic performance when autonomously assessing clinical imaging studies.
Materials And Methods:
A total of 206 imaging studies (i.e., radiography (n = 60), CT (n = 60), MRI (n = 60), and angiography (n = 26)) with unequivocal findings and established reference diagnoses from the radiologic practice of a large university hospital were accessed. Readings were performed uncontextualized, with only the image provided, and contextualized, with additional clinical and demographic information. Responses were assessed along multiple diagnostic dimensions and analyzed using appropriate statistical tests.
Results:
With its pronounced propensity to favor context over image information, the tool's diagnostic accuracy improved from 8.3% (uncontextualized) to 29.1% (contextualized, first diagnosis correct) and 63.6% (contextualized, correct diagnosis among differential diagnoses) (p ≤ 0.001, Cochran's Q test). Diagnostic accuracy declined by up to 30% when 20 images were re-read after 30 and 90 days and seemed unrelated to the tool's self-reported confidence (Spearman's ρ = 0.117 (p = 0.776)). While the described imaging findings matched the suggested diagnoses in 92.7%, indicating valid diagnostic reasoning, the tool fabricated 258 imaging findings in 412 responses and misidentified imaging modalities or anatomic regions in 65 images.
Conclusion:
GPT-4V, in its current form, cannot reliably interpret radiologic images. Its tendency to disregard the image, fabricate findings, and misidentify details, especially without clinical context, may misguide healthcare providers and put patients at risk.
Key Points:
Question Can Generative Pre-trained Transformer 4 Vision (GPT-4V) interpret radiologic images-with and without clinical context? Findings GPT-4V performed poorly, demonstrating diagnostic accuracy rates of 8% (uncontextualized), 29% (contextualized, most likely diagnosis correct), and 64% (contextualized, correct diagnosis among differential diagnoses). Clinical relevance The utility of commercial multimodal large language models, such as GPT-4V, in radiologic practice is limited. Without clinical context, diagnostic errors and fabricated findings may compromise patient safety and misguide clinical decision-making. These models must be further refined to be beneficial.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation I: X-ray and CT