Rapid patient-specific organ dose estimation in computed tomography scans via integration of radiomics features and
Wencheng Shao1, Xin Lin1, Ying Huang2
1Institute of Radiation Medicine, Fudan University, Shanghai, China.
Background:
Computed tomography (CT) offers detailed cross-sectional images of internal anatomy for disease detection but carries a risk of solid cancer or blood malignancies due to exposure to X-ray radiation. This study aimed to develop a new method to quickly predict patient-specific organ doses from CT examinations by training neural networks (NNs) based on radiomics features.
Methods:
CT Digital Imaging and Communications in Medicine (DICOM) image data were exported to DeepViewer, a clinical autosegmentation software, to segment the regions of interest (ROIs) for patient organs. Radiomics feature extraction was performed based on the selected CT data and ROIs. Reference organ doses were computed using Monte Carlo (MC) simulations. Patient-specific organ doses were predicted by training a NN model based on radiomics features and reference doses. For the dose prediction performance, the relative root mean squared error (RRMSE), mean absolute percentage error (MAPE), and coefficient of determination (R2) were evaluated on the test sets. The robustness of the NN model was evaluated via the random rearrangement of patient samples in the training and test sets.
Results:
The maximal difference between the reference and predicted doses was less than 1 mGy for all investigated organs. The range of MAPE was 1.68% to 5.2% for head organs, 11.42% to 15.2% for chest organs, and 5.0% to 8.0% for abdominal organs; the maximal R2 values were 0.93, 0.86, and 0.89 for the head, chest, and abdominal organs, respectively.
Conclusions:
The radiomics feature-based NN model can achieve accurate prediction of patient-specific organ doses at a high speed of less than 1 second using a single central processing unit, which supports its use as a user-friendly online clinical application.