Abstract:
A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process.