Related Experiment Video
Updated: Jun 9, 2025

Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
External evaluation of a commercial artificial intelligence-augmented digital auscultation platform in valvular heart
Valentina Roquemen-Echeverri1, Peter G Jacobs1, Evan F Shalen2
1Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA.
Objective:
There are few studies evaluating the accuracy of commercially available AI-powered digital auscultation platforms in detecting valvular heart disease (VHD). Therefore, the utility of these systems for diagnosing clinically significant VHD remains unclear. We conducted a comprehensive external evaluation of the Eko murmur analysis software (EMAS) and report its accuracy in detecting murmurs associated with VHD using echocardiography (ECHO) as the reference standard.
Methods:
We analyzed phonocardiogram (PCG) and ECHO data from 1,029 individuals (461 females, mean (SD) age: 61 (29) years, BMI: 29 (9)) at a single academic medical center. PCGs were recorded using the EkoDUO and EkoCORE stethoscopes from the four standard auscultation positions immediately before transthoracic ECHO (TTE) testing. TTE diagnostics were used as reference to calculate the EMAS sensitivity and specificity in detecting murmurs associated with VHD. The 95% confidence intervals are reported.
Results:
Of the 4,081 PCGs, 79% were of sufficient quality for murmur analysis. The sensitivity and specificity of the EMAS in detecting VHD were 39.3% (95% CI: 37.2-41.3) and 82.3% (95% CI: 80.0-84.5), respectively. EMAS sensitivity in detecting murmurs associated with common VHD types was 62.5%, 75.0%, 88.9%, and 63.3% for moderate-severe and severe cases of mitral stenosis, aortic regurgitation, aortic stenosis, and mitral regurgitation, respectively.
Conclusion:
The EMAS algorithm exhibits limited overall sensitivity in detecting VHD. The sensitivity of the algorithm varies across VHD types. These findings suggest that EMAS can be used for diagnosis of specific lesions, but not all VHD types, which limits its clinical applicability as a screening tool.
Related Concept Videos
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: