Effects of radiotherapy dose and application time on the load-to-failure values of teeth filled with different
Ozgun Gulderen1, Esma Saricam2, Sedef Gökhan Açikgöz3
1Department of Endodontics, Faculty of Dentistry, Ankara Yildirim Beyazit University, Ayvali Mah. 150. Sk. Etlik, Ankara, Turkey.
Background:
The materials used in root canal filling and radiotherapy (RT) application can affect the load-to-failure of the teeth. This study aimed to compare the load-to-failure of the teeth filled with AH Plus (AHP) or AH Plus bioceramic (AHPB) before or after 60 Gy- and 70 Gy-dose radiotherapy.
Materials And Methods:
One hundred and ten maxillary incisors were endodontically prepared up to ProTaper Next X4 instruments. The teeth were randomly divided into 5 main groups as: non-irradiated, root canal treatment (RCT) before 60 Gy radiotherapy, RCT before 70 Gy radiotherapy, RCT after 60 Gy radiotherapy, RCT after 70 Gy radiotherapy. These groups were divided into 2 subgroups for filling material: AHP ve AHPB. After filling and radiotherapy procedures, the teeth were fixed on the thermoplastic mask plane. The plane were placed in the middle of a rectangular prism shaped glass phantom, and irradiated via a linear accelerator device. The teeth were then embedded in cylindrical acrylic blocks and the force (N) that caused the fracture was recorded under the Universal testing device. Student t-test was used for statistical comparisons. Statistical significance level was determined as p < 0.05.
Results:
After 70 Gy dose radiotherapy, the group filled with AHPB showed statistically significantly lower fracture strength than the group filled with AHP (p < 0.05). In the control group, before 60 Gy RT group, after 60 Gy RT group, and before 70 Gy RT group, the sealers had statistically significantly similar load-to-failure. (p > 0.05).
Conclusion:
The group filled with AHPB caused a lower fracture strength than the group filled with AHP following a 70 Gy dose of RT. The sealers in the control group, before 60 Gy RT group, after 60 Gy RT group, and before 70 Gy RT group exhibited comparable load-to-failure values.
More Related Videos
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses