Related Experiment Video
Updated: Jun 9, 2025

Design and Optimization Strategies of a High-Performance Vented Box
Published on: June 9, 2023
Indoor overheating and mitigation of converted lofts in London, UK
Xiaoyi Li1, Jonathon Taylor1, Phil Symonds1
1UCL Institute for Environmental Design and Engineering, The Bartlett School Environment, Energy & Resources, University College London (UCL), London, UK.
Abstract:
In the UK, there has been an increase in the number of loft conversions, driven by demands for increased floor areas of dwellings to accommodate more individuals or increase property values. While rooms directly underneath roofs are known to have increased overheating risks, there is little research available that quantifies this risk, and how to mitigate it cost-effectively. This paper seeks to evaluate overheating risks in loft conversions, using integrated environmental solutions virtual environment to dynamically simulate indoor temperatures in a semi-detached dwelling in London, UK, under current and future (2050s and 2080s medium and high emissions) climate scenarios. Adaptive overheating risk and energy consumption are calculated with and without passive overheating adaptations that reduce solar gains, increase ventilation, or add thermal insulation. Marginal abatement cost curves (MACC) are then used to select the most cost-effective adaptations based on installation and ongoing energy consumption costs. Results estimate 11,340-12,210 more summertime Category I overheating degree-hours for the loft than conventional bedrooms in the dwelling under the current climate; total category I loft overheating degree-hours may increase to 20,319 by 2080. While external shutters and night-purge ventilation were the most effective at reducing overheating degree-hours (96% and 89%, respectively), the most cost-effective solutions considering capital and ongoing costs are ventilation strategies, including night-time purge ventilation, advance ventilation and cross ventilation. Passive adaptations are not capable of eliminating overheating entirely, and by the 2080s active cooling is likely to be required to maintain comfortable indoor conditions in lofts.
Practical Application:
Converted lofts - present in 5.8% of English and 10.8% of London dwellings - are at significantly elevated risk of high indoor temperatures relative to conventional rooms. Passive adaptations such as ventilation and shading can effectively mitigate loft overheating until around 2080, after which active measures become necessary. When capital and ongoing costs are considered, the most cost-effective heat mitigating adaptations are night and advance ventilation and internal curtains/blinds. Heat mitigating adaptations for converted lofts should become mandatory, and such spaces should not be occupied by the vulnerable or elderly during hot weather.
More Related Videos
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Mass Concreting
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...