Related Experiment Video
Updated: Jun 9, 2025

Establishing a Silicosis Rat Model via Exposure of Whole-Body to Respirable Silica
Published on: October 28, 2022
Measurements of dust and respirable crystalline silica during indoor demolition and renovation
Johanne Ø Halvorsen1,2, Pål Graff1,2, Elin Lovise Folven Gjengedal2
1STAMI, National Institute of Occupational Health, Gydas Vei 8, 0363 Oslo, Norway.
Abstract:
Increased focus on renovating and maintaining the existing building stock is an integral part of the circular economy, however this might pose challenges to workers health. The aim of this study was to assess the renovation workers' exposure to inhalable dust, thoracic dust, respirable dust, and respirable crystalline silica (RCS). Personal aerosol samples were collected as full shift samples from 92 workers to a total of 407 samples. Fourteen locations around Oslo, Norway was visited for multiple days with repeated measurements of the same individual. Particulate matter from 3 aerosol fractions, respirable, thoracic, and inhalable, were analyzed gravimetrically, and the respirable fraction was analyzed for RCS by NIOSH 7500 method for X-ray diffraction (XRD) with low temperature plasma ashing sample preparation. The total measured concentrations of respirable dust (n = 192) had a geometric mean (GM) of 0.88 mg/m3, RCS concentrations (n = 182) had a GM of 0.040 mg/m3, thoracic dust (n = 131) had GM 2.4 mg/m3, and inhalable dust (n = 84) had a GM of 8.5 mg/m3. The maximum measured concentrations were 29 mg/m3, 3.2 mg/m3, 65 mg/m3, and 163 mg/m3, respectively. Workdays involving tasks such as mechanical demolition and clearing out demolished materials led to the highest exposure levels of both dust and RCS. However, other workers at the renovation sites were indirectly exposed to a considerable amount of RCS. This study revealed substantial exposure to both RCS and dust during renovation, and protective measures are warranted to reduce exposure levels in the industry.
More Related Videos
09:29An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
Published on: May 13, 2020
09:44Laboratory Drop Towers for the Experimental Simulation of Dust-aggregate Collisions in the Early Solar System
Published on: June 5, 2014
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Deleterious Substances in Aggregate
Another type of impurity is clay and fine material that...
Fineness of Cement
Direct...
Efflorescence in Masonry
While initial efflorescence is common post-construction and can be cleaned with water and a brush, in certain instances, efflorescence can reappear and gradually diminish over time as salts are leached out...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...