Related Experiment Video
Updated: Jun 9, 2025

Making MR Imaging Child's Play - Pediatric Neuroimaging Protocol, Guidelines and Procedure
Published on: July 30, 2009
Low-Field MRI for Dental Imaging in Pediatric Patients With Supernumerary and Ectopic Teeth: A Comparative Study of
Ines Willershausen1, Stefania Evangeliou, Hans-Peter Fautz
1From the Department of Orthodontics and Orofacial Orthopedics, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany (I.W., S.E., L.G.); Imaging Science Institute, University Hospital Erlangen, Erlangen, Germany (H.-P.F., P.A.); Department of Radiology, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany (M.S.M., M.Z., M.U., M.K.); and Center for Clinical Studies, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany (A.S.).
Objectives:
This study sought to elucidate the diagnostic performance of 0.55 T magnetic resonance imaging (MRI) for pediatric dental imaging, specifically in terms of the image quality (IQ) for detecting ectopic and/or supernumerary teeth, compared with routine ultra-low-dose computed tomography (ULD-CT) of the jaw.
Materials And Methods:
A total of 16 pediatric patients (mean age: 12.4 ± 2.6 years, range: 9-17 years) with ectopic and/or supernumerary teeth screened from January 2023 to January 2024 were enrolled in this prospective, single-center study. All patients underwent ULD-CT as the clinical reference standard and 0.55 T MRI as the study scan on the same day. A 0.6-mm isotropic 3-dimensional T1w FLASH sequence was developed with a dedicated field of view of the upper and lower jaws. ULD-CT was performed using a new single-source computed tomography (CT) scanner equipped with a tin filter (Sn100, slice thickness: 1 mm, quality reference mAs: 24). The IQ for the tooth axis, the tooth length, the tooth root, root resorptions, cysts, the periodontal ligament space, and the mandibular canal was evaluated twice by 3 senior readers using a 5-point Likert scale (LS) (LS score of 1: insufficient, 3: reduced IQ but sufficient for clinical use, and 5: perfect) and compared between both methods. Subsequently, the results were dichotomized into nonvalid (LS score of ≤2) and valid (LS score of ≥3) for clinical use.
Results:
A total of 49 ectopic and/or supernumerary teeth in 16 pediatric patients were investigated using ULD-CT (CTDI: 0.43 ± 0.09 mGy) and 0.55 T MRI. The mean MRI acquisition time was 9:45 minutes. Motion artifacts were nonsignificantly different between 0.55 T MRI and ULD-CT ( P = 0.126). The IQ for the tooth axis, the tooth root, root resorptions, and cysts was similar between the methods. The IQ for the periodontal ligament space and tooth length favored ULD-CT by 14% (confidence interval [CI]: 4.3%-24%) and 7.5% (CI: 1.8%-13%), respectively, whereas that for the mandibular canal favored 0.55 T MRI by -35% (CI: -54%-16%). Sufficient IQ was found especially for cystic lesions (CT: 100% sufficient, MRI: 95% sufficient), the tooth root (CT: 100%, MRI: 98%), root resorptions (CT: 94%; MRI: 85%), the tooth axis (CT: 100%; MRI: 98%), and the tooth length (CT: 99%; MRI: 91%).
Conclusions:
The findings indicate that 0.55 T MRI is a feasible, radiation-free technique for delineating ectopic and/or supernumerary teeth in pediatric patients. Nevertheless, to date, 0.55 T MRI has not yet been able to provide an optimal IQ for all anatomical tooth and jaw structures. In cases of advanced clinical indications that require optimal spatial resolution, high-resolution CT or cone-beam CT may still be necessary.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System IV: CMRI