A Long Atrial Electromechanical Interval is Associated with Arrhythmic Recurrence after Catheter Ablation: How to
Valentina Barletta1, Antonio Maria Canu1, Matteo Parollo1
1Department of Cardiac-Thoracic and Vascular, Second Division of Cardiology, Pisa University Hospital, Pisa, Italy.
Background:
Atrial fibrillation (AF) results in electrical and structural remodeling of the atria, which extent is known to be associated with a higher AF recurrence rate after catheter ablation (CA). Recently, a novel echocardiographic parameter derived from tissue Doppler imaging (TDI) [PA-TDI] has been introduced to assess the total atrial activation time, as a noninvasive surrogate of fibrosis and remodeling. The aim of the study is to investigate the role of PA-TDI interval as a predictor of AF ablation efficacy.
Methods:
We retrospectively included patients with paroxysmal symptomatic drug-refractory AF referred to our institution for CA procedure, who presented sinus rhythm at admission. A complete transthoracic echocardiogram was performed before the ablation procedure, including the assessment of PA-TDI interval.
Results:
From January 2015 to April 2018, 128 patients (mean age: 61.86 ± 9.08 years, 68% male, body surface area: 1.97 ± 0.21 mq, body mass index: 26.98 ± 3.86 kg/mq, and ejection fraction: 59% ±6.06%) with symptomatic drug-refractory AF who received radiofrequency CA were enrolled. During the follow-up of 15.80 ± 6.7 months, 30 patients (23%) developed AF recurrence out of the blanking period. Compared with those without recurrence (group 1), patients with recurrence (group 2) had a larger left atrium (LA) size (Group 1 vs. Group 2: mean LA area: 22.2 ± 4.6 cmq vs. 25 ± 6.6 cmq, P = 0.015; mean indexed LA volume: 35 ± 10 mL/mq vs. 40 ± 12 mL/mq, P = 0.04) and longer PA-TDI interval (Group 1 vs. Group 2: 162 ± 33 ms vs. 133 ± 26 ms, P < 0.0001). A cutoff of PA-TDI > 150 ms identified patients with recurrence after ablation with a sensibility of 82% and specificity of 83% (area under the curve 0.879).
Conclusions:
The total activation time assessed by PA-TDI is an independent predictor of AF recurrence and can be used to predict the efficacy of transcatheter ablation.
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias