Related Experiment Video
Updated: Jun 9, 2025

Two-way Valorization of Blast Furnace Slag: Synthesis of Precipitated Calcium Carbonate and Zeolitic Heavy Metal Adsorbent
Published on: February 21, 2017
Evaluation of the Na-EDTMP/borax system as a non-dispersing, high temperature retarder for oil well cement
Dominik Staude1, Johann Plank1
1Technical University of Munich, Construction Chemistry, Lichtenbergstraße 4, 85747, Garching, Germany.
Abstract:
For well cementing at temperatures above 120 °C, thermal thinning depicts a major problem, promoting particle sedimentation via decreasing slurry viscosities. This is partly caused by dispersing properties of common high temperature retarder systems and can lead to imperfect zonal isolation, endangering the stability of the wellbore. Counteracting additives tend to start losing their effectiveness at temperatures >140 °C. Other options are often not economically sufficient, increase system complexity or show negative interactions with other additives. Hence, this work presents a comprehensive study on the sodium ethylenediamine tetra(methylene phosphonate) (Na-EDTMP)/borax retarder system, which was found to combine sufficient retardation with low thermal thinning, leading to an enhanced slurry stability at high temperatures. Thickening times (TT's) from 7 to 13 h (increasing with temperature) were achieved from atmospheric pressure and 50 °C up to high pressures and temperatures (HP/HT) of 19.0 kpsi and 200 °C bottom hole circulating temperature (BHCT). Furthermore, On/off-cycle HP/HT consistometer tests at 160 and 190 °C and rheological measurements were performed to examine stability of the slurry's viscosity. Experiments with fluid-loss additives show potential compatibility with other additives. Total retarder dosages of 0.97-2.64 % bwoc (by weight of cement) were applied. Compared to prior literature, higher Na-EDTMP/borax ratios (0.29-0.34 vs. 0.055) were found to improve retarding performance probably by enhancing synergetic effects. The slurries featured a sufficient initial viscosity (<40 Bc) and a constant pumpability (10-25 Bc) during the tests followed by a swift setting and compressive strength (CS) development. Additionally, high slurry stability was shown and compatibility with common fluid-loss additives is probable. Main disadvantage was the relatively high sensitivity of the system, especially at moderate temperatures, requiring exact dosage. Summarizing, the Na-EDTMP/borax retarder system might present a low-complexity opportunity for common high temperature retarders, avoiding thermal thinning while improving slurry stability.
Related Concept Videos
Retarders
The function of retarders is to delay the setting of concrete, and this effect can be measured using a penetration test. The retardation process involves adding...
Design Example: Managing Concrete Workability
Testing Water Quality
Types of Cement II
Washing, Drying, and Ignition of Precipitates
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...