Related Experiment Video
Updated: May 10, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
From novice to Expert: Reducing Breast Imaging rejection rates through physician mentorship in Advanced Practice
Clodagh Starrs1, Sima Rabinowitz2, Erin Moshier3
1Department of Radiation Oncology, The Mount Sinai Hospital, New York, NY, United States.
Purpose:
The study's goal was to evaluate the impact of a Radiation Oncologist (RO)-Radiation Therapist (RTT) mentorship on image approval rates for a breast population undergoing radiation therapy in a high-volume practice. The mentorship was undertaken within a large health system in partial fulfillment of the Expert Practice Module for a Masters (MSc) in Advanced Practice Radiotherapy and Oncology.
Methods:
Images were retrieved from the MOSAIQ EMR on breast diagnostic code. 1,295 images/115 patients were reviewed pre-mentorship (October 2019-March 2020) and compared with 1,047 images/91patients during/post-mentorship (April 2020-September 2020). The Anderson-Gill (AG) model was used to estimate the hazard ratio for image rejection. Rejected images were classified by reason and compared using Fisher's exact test. Concordance data (RO/RTT image rejection) were collected during Phase Three of the mentorship.
Results:
Of 115 patients assessed pre-mentorship, 16 (14 %) had at least 1 image rejected at any session. Of 91 patients assessed post-mentorship, 8 (9 %) had at least 1 image rejected. Likelihood of image rejection decreased by 54 %, with a hazard ratio of 0.46 [95 % CI: 0.24, 0.88]; p = 0.0195. Reasons for image rejection differed pre- and post-mentorship. Poor imaging technique accounted for rejection of 9 of 24 images (37.5 %) before compared to 0 of 11 images (0 %) post-mentorship. Other reasons for image rejection: depth at isocenter (25 % pre-mentorship; 18 % post-mentorship), supraclavicular medial border position (12.5 % vs. 9.09 %), isocenter location (12.5 % vs. 0 %), arm position (4.17 % vs. 54.55 %); hip alignment (8.33 % vs. 18.18 %). Concordance rate was 100 %.
Conclusions:
The mentorship proved successful in elevating the RTT's skills and image approval rates, while contributing to improvements in departmental imaging best practices.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...