Related Experiment Video
Updated: Jun 9, 2025

Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Possibility to measure the volume of coronary sinus in contrast-enhanced computed tomography
Agnieszka Młynarska1, Rafał Młynarski1
1School of Health Sciences, Medical University of Silesia, Katowice, Poland.
Introduction:
Modern imaging techniques such as computed tomography (CT) can help in the assessment of coronary sinus volume in a vitro manner, but there is no comprehensive research on this topic so far. Hence, we decided to develop a methodology for measuring the volume of the coronary sinus in multi-detector CT and to try to apply it in practice.
Material And Methods:
Forty-nine patients (22 men) were included in this research, with a mean age of 70.08 ± 13.6 years. Scanning with retrospective ECG-gating was performed using a Toshiba Aquilion 64 (slice: 0.5 mm; helical pitch: 12.8; rotation time: 0.4 s). 80 ± 20 cm3 of non-ionic contrast was administered to each patient. The volume of coronary sinus and other data measurements were performed using Vitrea 2 workstations. The organ volume measurement function was used to measure volume objects in CT scans. To standardise the measurements, they were all performed to the place where the vein of Marshall reaches the coronary sinus. In cases of loss of vein of Marshall, the first lateral vein was used as the junction between the coronary sinus and the great cardiac vein.
Results:
The coronary sinus volume varied from 0.96 cm3 to 8.52 cm3. The average volume was 3.71 ± 1.64 cm3. There was a significant correlation between end diastolic volume and coronary sinus volume (r = 0.33, p = 0.02). In most cases the quality of visualisation was good - the average was calculated as 4.16 ± 0.87. The Thebesian valve was present in 22 cases (44.9%); however, no statistical relationship between the presence of the Thebesian valve and coronary sinus was observed.
Conclusion:
It is possible to visualise and calculate the volume of the coronary sinus in cardiac CT.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Acute Coronary Syndrome III: Diagnostic studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...