Comparison of Conventional and Virtual Non-contrast Abdominal Images Using the Third-Generation Dual-Source
1Radiology, Gazi University Faculty of Medicine, Ankara, TUR.
Purpose:
To determine the efficacy and safety of virtual unenhanced imaging by comparing the attenuation values of virtual and true unenhanced images acquired using third-generation dual-source dual-energy computed tomography (dsDECT).
Methods:
Single-energy non-contrast and dual-energy arterial and venous phase images of 97 patients who underwent triphasic abdominal computed tomography (CT) were included in this retrospective study. Virtual unenhanced images were generated for the arterial (a) and venous (v) phases using two dsDECT algorithms. The attenuation values were measured on the true and virtual unenhanced images of the liver, spleen, kidney, gallbladder, paraspinal muscle, aorta, subcutaneous fat, retroperitoneal fat, and renal cysts.
Results:
A statistically significant difference was observed between the attenuation values of true and virtual unenhanced images for all tissues (p < 0.001-0.025), except the venous phase virtual unenhanced images of the kidney, renal cysts, and gallbladder (p = 0.061-0.325). The proportion of cases with differences of ≥ 10 Hounsfield unit (HU) in the attenuation values between the virtual and true unenhanced images ranged from 3% to 8% for renal parenchyma, renal cysts, and gallbladder using this algorithm; however, this proportion was up to 90% for adipose tissue. No significant correlation was observed between the body mass index and attenuation differences between the true and virtual unenhanced images, except for those of the aorta and paraspinal muscle.
Conclusion:
Virtual unenhanced images acquired using third-generation dsDECT cannot replace true unenhanced images in clinical practice owing to the difference between the attenuation values and variability of attenuation between true and virtual unenhanced images.
More Related Videos
07:12Author Spotlight: Using Point-of-Care Ultrasound for Comprehensive Evaluation of the Abdominal Aorta
Published on: September 8, 2023
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...