Validity and reliability of velocity and power measures provided by the Vitruve linear position transducer
Santiago A Ruiz-Alias1,2, Deniz Şentürk3, Zeki Akyildiz4
1Department of Physical Education and Sports, Faculty of Sport Sciences, University of Granada, Granada, Spain.
Abstract:
This study aimed to determine the validity and between-day reliability of the mean velocity (MV), peak velocity (PV), mean power (MP), and peak power (PP) provided by the Vitruve linear position transducer at different submaximal loads in the free-weight and Smith machine back squat using GymAware as a reference point. Fourteen male sports science students (free-weight back squat one-repetition maximum [1RM]: 132.5 ± 28.5 kg, Smith machine back squat 1RM: 163.9 ± 30.4 kg) performed six experimental sessions, twice per week with 72 hours of rest. The first two included the assessment of the 1RM of both exercises. In the four remaining, both linear position transducers were simultaneously used to record MV, PV, MP, PP of each repetition during an incremental load test (i.e., 20, 40, 60, 80, 90% 1RM) with three minutes of rest between sets. Vitruve displayed both fixed and proportional bias for certain relative loads across all variables. Vitruve did not meet the validity criteria for all (MV, PP) or at least two (MP, PV) relative loads (Coefficient of variation [CV] > 10%; Pearson correlation < 0.70; Effect size > 0.60). MV, PV, MP, and PP recorded by Vitruve displayed acceptable reliability (CV < 10%) with superior reliability observed during a Smith Machine compared to free-weight back squat, and for velocity compared to power variables. Considering GymAware as a reference point, Vitruve was not valid for measuring velocity and power outcomes. Acceptable validity was observed only for PV in the Smith machine back squat, while the other variables-regardless of relative loads and exercise modes-were mostly inaccurate. All variables demonstrated acceptable reliability, with greater reliability noted in the Smith machine compared to the free-weight back squat exercise mode.
More Related Videos
Related Concept Videos
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Velocity and Position by Integral Method
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...
Velocity and Position by Graphical Method
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Relative Velocity in Two Dimensions
Velocity Potential