Related Experiment Video
Updated: Jun 9, 2025

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Active and passive sampling techniques in headwater streams to characterize acesulfame-K, pharmaceutical and
YingYing Liu1, Maria Digaletos2, Carol J Ptacek2
1Key Laboratory of Groundwater Resources and Environment, Ministry of Education, Jilin University, Changchun 130021, China; Jilin Provincial Key Laboratory of Water Resources and Environment, Jilin University, Changchun 130021, China; National and Local Joint Engineering Laboratory for Petrochemical Contaminated Site Control and Remediation Technology, Jilin University, Changchun 130021, China; Department of Earth and Environmental Sciences, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
Abstract:
On-site wastewater disposal systems have been identified as a source of contamination for nutrients and emerging contaminants (ECs), such as artificial sweeteners and pharmaceutical compounds. The passive sampling technique Polar Organic Chemical Integrative Sampler (POCIS) and phosphorus sampler (P-Trap) have been widely used for tracking polar organic contaminants and total dissolved phosphorus in environmental waters such as surface water and wastewater. However, limited studies have been conducted on application of passive sampling techniques to track contamination in headwater streams impacted by on-site wastewater disposal systems. In this study, active sampling (discrete samples) and passive sampling (P-Trap and POCIS) techniques were applied in upstream and downstream locations at three rural hamlets to compare and track the contamination of total dissolved phosphorus (TDP) and seven ECs, including six pharmaceuticals and one artificial sweetener acesulfame-K (ACE-K), in the shallow headwater streams of rural hamlets in southern Ontario, Canada that exclusively rely on septic systems for wastewater disposal. Results show that POCIS and P-Trap yielded comparable time-weighted average (TWA) concentrations of target ECs and TDP, respectively, to mean concentrations of discrete samples during the seasonal (spring, summer, and fall) and two-week intensive study periods. Field-derived sampling rates (Rs-field) of target contaminants compared well to literature-reported values indicating POCIS and P-Trap were applicable in determining the concentrations of target contaminants in the investigated streams, even though some environmental factors, such as dry stream conditions and fouling, occurred during the sampling period. The low but stable Rs-field of ACE-K (∼0.001 L d-1) from this study indicates consistency in application of POCIS for capturing ACE-K. The results of this study provide insight into the confidence and limitations for using POCIS and P-traps to track ECs and TDP in shallow headwater streams impacted by septic systems.
More Related Videos
08:49Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
10:53Concentration of Virus Particles from Environmental Water and Wastewater Samples Using Skimmed Milk Flocculation and Ultrafiltration
Published on: March 17, 2023
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...