Related Experiment Video
Updated: Jun 9, 2025

Alternative In Vitro Methods for the Determination of Viral Capsid Structural Integrity
Published on: November 16, 2017
Efficacy of Virucidal Treatments against Poliovirus Type 1 Deposited on Stainless-Steel Carriers
Cory Chiossone1, Tanya Kapes1, Robert Good1
1Microbac Laboratories, Inc., Sterling, VA 20164, USA.
Abstract:
Safe containment of infectious poliovirus (PV) within Poliovirus-Essential Facilities (PEFs) will require the implementation of reliable PV-inactivation approaches for decontaminating work surfaces. Such approaches should be demonstrated empirically to display adequate efficacy at the use temperature, and the contact times required should be characterized to ensure efficacy. Such efficacy is judged by the ability of the inactivation approach to completely inactivate any PV deposited, with the demonstrated total log10 reduction in PV titer being as high as empirically achievable. We screened several approaches for their efficacy in inactivating wild-type PV type 1 Chat strain experimentally deposited on stainless-steel carriers at room temperature. On the basis of the results, we selected two approaches (5000 ppm sodium hypochlorite in water and 95% v/v ethanol in water) for further characterization for repeatability of efficacy (log10 reduction in PV titer) and time kinetics of inactivation. We now report that both PV-inactivation approaches, which should be readily available to all PEF laboratories globally, fulfill the expectations expressed above, with 5000 ppm sodium hypochlorite reproducibly causing ≥5.38 log10 inactivation and 95% ethanol reproducibly causing ≥4.46 log10 inactivation of PV on stainless-steel surfaces within a 5 min contact time at room temperature.
More Related Videos
07:00Failure of Cleaning Verification in Pharmaceutical Industry Due to Uncleanliness of Stainless Steel Surface
Published on: August 11, 2017
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Antimicrobial Effectiveness
Hand hygiene
Hand washing...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...