Related Experiment Video
Updated: Jun 9, 2025

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Virtual Instruments for Peak-Overlapping Studies to Determine Low- and High-Concentration Components with Ion
1Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna Pot 113, SI-1000 Ljubljana, Slovenia.
Abstract:
We developed the LabVIEW-based virtual instruments (VIs) to bridge a gap in commercial software and to enable systematic peak-overlapping studies to recognise the concentration levels enabling reliable simultaneous determination of major and minor constituents in samples with wide concentration proportions. The VIs were applied to a case study of the ion chromatographic determination of potassium as minor and sodium as a major ion with an IonPac CS12A column and 50 μL injection loop. Two successive studies based on multilevel two-factorial response surface experimental designs, (1) a model peak-overlapping study based on single-ion injections, and (2) an accuracy and precision study, provided guidelines for real sample analyses. By adjusting sample dilutions so that the sodium mass concentration was set to 340 mg/L, the simultaneous determination of potassium in the presence of sodium was possible in samples with sodium over potassium concentration ratios between 14 and 341. The relative expanded uncertainty associated with potassium ion determination was between 0.52 and 4.4%, and the relative bias was between -3.8 and 1.9%. We analysed Ringer's physiologic solutions, standard sea, trisodium citrate anticoagulant, and buffered citrate anticoagulant solutions. We confirmed that the VI-supported peak-overlapping studies contributed to the quality of results by enabling the evidence-based choices of concentration levels adjusted by a dilution.
More Related Videos
08:40Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Ion-Exchange Chromatography
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Instrumentation