Experimental Study on the Strength and Durability of Manufactured Sand HPC in the Dalian Bay Undersea Immersed Tube
Yuefeng Sun1, Shanshan Song2,3, Hongfa Yu2
1CCCC First Harbor Bureau No. 3 Engineering Co., Ltd., Dalian 116000, China.
Abstract:
The usage of manufactured sand concrete is widespread in modern engineering, and it is important to study its performance to improve the overall engineering quality. This paper presents an experimental study on the working performance and durability of 12 groups of manufactured sand high-performance concrete (MSHPC) with varying mix ratios, in the context of the construction of the Dalian Bay undersea immersed tube tunnel. The study reveals that the stone powder content significantly affects the physical and mechanical properties, as well as the durability, of manufactured sand concrete. At an approximately 9% stone powder content, the concrete achieves the highest slump and best workability. However, excessive stone powder reduces early crack resistance. Furthermore, an optimal stone powder content (ranging from 5% to 13%) enhances the compressive strength, with the 28-day compressive strength reaching 60 MPa at a 13% stone powder content, while the effect on the splitting tensile strength is negligible. The stone powder content does not significantly impact impermeability and frost resistance, but at 7-9%, the RCM method shows the lowest chloride ion diffusion coefficient. Additionally, a lower water-binder ratio enhances resistance to chloride ion diffusion. High-performance RCM concrete with a 9% stone powder content was used in the construction of the Dalian Bay Cross-Harbor Tunnel, achieving 28-day and 56-day compressive strengths of C45 and C50, respectively, an impermeability grade of P14, a chloride ion diffusion coefficient of 1.9 × 10-12 m2/s, and a frost durability index of 92%, meeting the project's 100-year lifespan design requirements.
Related Concept Videos
Design Example: Aggregate Gradation
The grading, or particle-size distribution, of sand is determined using sieve analysis, with standard sizes ranging from 150 μm to 10 mm (ASTM No. 100 sieve to 3⁄8 in. sieve). Sand is...
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Testing Water Quality
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Design Example: Managing Concrete Workability