Related Experiment Video
Updated: Jun 9, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Initial Findings Concerning the Latest Self-Expandable Evolut FX Valve: A Report Using OCEAN-TAVI Registry Data
Fumiaki Yashima1, Masanori Yamamoto2, Shinichi Shirai3
1Department of Cardiology, Saiseikai Utsunomiya Hospital, Tochigi, Japan.
Abstract:
Data concerning the clinical effect of the latest-generation self-expandable transcatheter heart valve (Evolut FX) remain limited. We aimed to assess the in-hospital outcomes of 3 bioprosthetic valves (Evolut EPO, PRO+, and FX). We analyzed data from a Japanese multicenter registry involving 634 consecutive patients who underwent transcatheter aortic valve replacement with Evolut FX up until October 2023. Patients who underwent transcatheter aortic valve replacement with Evolut EPO between 2018 and 2020 (n = 1,128), and those with Evolut EPO+ between 2020 and 2023 (n = 1,696) served as the control groups. The exclusion criteria comprised patients on dialysis with a history of infective endocarditis or with insufficient data. Unmatched comparisons among the 3 valves were conducted, followed by a propensity score-matched comparison between Evolut EPO+ and FX. In the unmatched cohort, among the Evolut EPO, PRO+, and FX groups, all vascular complications (7.8% vs 5.2% vs 4.5%, respectively, p <0.01) and new pacemaker implantation rates (11.2% vs 6.1% vs 7.7%, respectively, p <0.01) differed significantly. In the propensity score-matched analysis, the rate of all bleeding events was significantly higher in the Evolut EPO+ group (11.0%) than in the FX group (7.0%) (p = 0.02), whereas all vascular complications (4.6% vs 4.6%, respectively, p = 1.00) and new pacemaker implantation (5.9% vs 7.6%, respectively, p = 0.28) rates were comparable. The incidence of stroke in the FX group was approximately half that of the EP+ group (3.7% vs 1.9%, p = 0.095), without statistical significance. In conclusion, compared with the Evolut EPO+, Evolut FX was associated with a lower incidence of in-hospital bleeding complications and may reduce the incidence of in-hospital stroke.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Aortic Regurgitation I: Introduction
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse II: Assessment and Management
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...