Related Experiment Video
Updated: Aug 3, 2026

Practical Considerations in Studying Metastatic Lung Colonization in Osteosarcoma Using the Pulmonary Metastasis Assay
Published on: March 12, 2018
Concordance of Whole-Slide Imaging and Conventional Light Microscopy for Assessment of Pathologic Response Following
Julie S Deutsch1, Daphne Wang2, Krista Y Chen2
1Department of Dermatology, Johns Hopkins University School of Medicine, Baltimore, Maryland; Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, Maryland.
Abstract:
Pathologic response is an endpoint in many ongoing clinical trials for neoadjuvant regimens, including immune checkpoint blockade and chemotherapy. Whole-slide scanning of glass slides generates high-resolution digital images and allows for remote review and potential measurement with image analysis tools, but concordance of pathologic response assessment on digital scans compared with that on glass slides has yet to be evaluated. Such a validation goes beyond previous concordance studies, which focused on establishing surgical pathology diagnoses, as it requires quantitative assessment of tumor, necrosis, and regression. Further, as pathologic response assessment is being used as an endpoint, such concordance studies have regulatory implications. The purpose of this study was 2-fold, which was as follows: first, to determine the concordance between pathologic response assessed on glass slides and that assessed on digital scans, and second, to determine if pathologists benefited from using measurement tools when determining pathologic response. To that end, hematoxylin and eosin-stained glass slides from 64 non-small cell lung carcinoma specimens were visually assessed for percent residual viable tumor (%RVT). The sensitivity and specificity for digital vs glass reads of pathologic complete response (0% RVT) and major pathologic response (≤10% RVT) were all >95%. When %RVT was considered as a continuous variable, the intraclass correlation coefficient of digital vs glass reads was 0.94. The visual assessments of pathologic response were supported by pathologist annotations of residual tumor and tumor bed areas. In a separate subset of hematoxylin and eosin-stained glass slides, several measurement approaches to quantifying %RVT were performed. Pathologist estimates strongly reflected measured %RVT. This study demonstrates the high level of concordance between glass slides evaluated using light microscopy and digital whole-slide images for pathologic response assessments. Pathologists did not require measurement tools to generate robust %RVT values from slide annotations. These findings have broad implications for improving clinical workflows and multisite clinical trials.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
05:00Author Spotlight: Enhancing Multicolor Fluorescence Localization in Lung Carcinoma Sample
Published on: November 21, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET