Related Experiment Video
Updated: Jun 9, 2025

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Radiation dose to health care workers measured by thermoluminescent dosimetry
M Alakhras1, D S Al-Mousa2, B Al Mohammad1
1Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan.
Aim:
To evaluate radiation dose among physicians, nurses, nuclear medicine (NM) technicians, and radiographers at a single institution and to compare the difference in the measured dose during COVID-19 with other periods.
Materials And Methods:
A retrospective analysis of the occupational radiation doses received by all workers in diagnostic radiography and NM departments at a single institution during a 5-year period (2018-2022) was performed. Dose measurements were recorded for 94 radiology personnel: radiographers, NM technicians, physicians, and nurses. In addition to descriptive statistics, the Mann-Whitney U-test was used to compare the average annual effective dose between male and female workers and between the periods before and during COVID-19. Kruskal-Wallis test was used to compare effective radiation doses from different quadrants.
Results:
The annual average effective doses were found to be between 0.58 and 0.72 mSv for males and 0.68 and 0.85 mSv for females. All radiographers, 86% of nurses, and 69% of physicians have received annual average effective doses below 0.99 mSv. The average annual effective doses for all radiation workers were similar in the period before COVID-19 when compared to the period during COVID-19 except for nurses who had significantly lower (P<0.05) doses before COVID-19.
Conclusion:
The average annual effective doses of radiation workers during 2018-2022 were well below the annual dose limit. A relatively higher average effective dose was received among NM technicians compared with other radiation occupational workers. While the caseload during the COVID-19 pandemic was lower due to government policies, the radiation dose to healthcare workers during the pandemic was similar to that before the pandemic.
More Related Videos
08:23An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
Published on: December 25, 2021
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Absorption of Radiation