[Clinical Validation of a Prototype Smart Non-Invasive Pregnancy Glucose Monitor]
Heqing Lu1, Lirui Cheng2, Qiaoling Du1
1Shanghai First Maternity and Infant Hospital, School of Medicine, Tongji University, Shanghai, 201204.
The aim of this study is to evaluate the effectiveness of a smart non-invasive blood glucose monitor prototype during pregnancy through clinical validation. The monitor utilizes near-infrared spectroscopy combined with AI big data analysis of photoelectric volumetric pulse wave data to achieve non-invasive monitoring of blood glucose in women during pregnancy. The research team developed a monitor that employs a sensing chip, effectively overcoming the problems of weak signals and individual differences in non-invasive blood glucose monitoring. The user experience is enhanced by visualizing the test results on the accompanying cell phone APP (application) of the smart non-invasive pregnancy blood glucose monitor. Clinical validation revealed that the non-invasive monitoring data for pregnant women aged 20~30 years significantly differed from those obtained via traditional blood glucose measurement methods, whereas no significant difference ( P<0.05) was observed for pregnant women aged 31~42 years. The study concluded that further calibration of the monitor and an expansion of the sample size are necessary to enhance consistency with invasive glucose monitoring results.
The aim of this study is to evaluate the effectiveness of a smart non-invasive blood glucose monitor prototype during pregnancy through clinical validation. The monitor utilizes near-infrared spectroscopy combined with AI big data analysis of photoelectric volumetric pulse wave data to achieve non-invasive monitoring of blood glucose in women during pregnancy. The research team developed a monitor that employs a sensing chip, effectively overcoming the problems of weak signals and individual differences in non-invasive blood glucose monitoring. The user experience is enhanced by visualizing the test results on the accompanying cell phone APP (application) of the smart non-invasive pregnancy blood glucose monitor. Clinical validation revealed that the non-invasive monitoring data for pregnant women aged 20~30 years significantly differed from those obtained via traditional blood glucose measurement methods, whereas no significant difference ( P<0.05) was observed for pregnant women aged 31~42 years. The study concluded that further calibration of the monitor and an expansion of the sample size are necessary to enhance consistency with invasive glucose monitoring results.